PRODUCT SHEET

Golden Gate | High Temperature ATR

The High Temperature Golden Gate option enables analyses up to 300 oC, suitable for polymer studies and other temperature-ramping experiments.

Features and Purposes

High temperature capability: Solid and liquid samples can be heated up to 300 oC; suitable for adhesive, coating, paint, corrosive, catalytic, cement, soil, protein, drug substance, and acid-soap phase transition applications.
Robust brazed monolithic diamond ATR: Adhesive-free, non-laminated monolithic diamond with brazed tungsten carbide mounting enables excellent thermal and chemical robustness, scratch resistance, and a wide spectral range.
USB controller and PC based control software: PC software and USB controller save lab space and allow real-time monitoring of temperature curves, automation, and easy data logging.
Pressure tower: Reduced sample-to-sample variation with repeatable and reproducible load application pre-set to 80 lbs (adjustable to 180lbs upon request).

DOCUMENTS AND RESOURCES
USB Temperature Controller Manual
Quick Start Guide For Golden Gate ATR Manual
High Temperature Heated Golden Gate Manual
Golden Gate Torque KnobScrew Replacement Kit Manual
Golden Gate Manual
PRODUCT SHEET

Golden Gate | High Temperature ATR

The High Temperature Golden Gate option enables analyses up to 300 oC, suitable for polymer studies and other temperature-ramping experiments.

Features and Purposes

High temperature capability: Solid and liquid samples can be heated up to 300 oC; suitable for adhesive, coating, paint, corrosive, catalytic, cement, soil, protein, drug substance, and acid-soap phase transition applications.
Robust brazed monolithic diamond ATR: Adhesive-free, non-laminated monolithic diamond with brazed tungsten carbide mounting enables excellent thermal and chemical robustness, scratch resistance, and a wide spectral range.
USB controller and PC based control software: PC software and USB controller save lab space and allow real-time monitoring of temperature curves, automation, and easy data logging.
Pressure tower: Reduced sample-to-sample variation with repeatable and reproducible load application pre-set to 80 lbs (adjustable to 180lbs upon request).

DOCUMENTS AND RESOURCES
USB Temperature Controller Manual
Quick Start Guide For Golden Gate ATR Manual
High Temperature Heated Golden Gate Manual
Golden Gate Torque KnobScrew Replacement Kit Manual
Golden Gate Manual

Contact us to discover the offer dedicated to this product!

Compila il form per richiedere un preventivo.

Compila il form per richiedere un preventivo.