PRODUCT SHEET

Nicotinic Acid (210 – 260 nm)

Nicotinic Acid Reference Material consists of solutions with concentrations ranging from 6 to 24 mg/L prepared in 0.1 M hydrochloric acid. These are contained in high quality far UV quartz cells and supplied alongside a 0.1 M hydrochloric acid blank cell.

This material is designed to qualify the accuracy and linearity of the absorbance scale of spectrophotometers with a bandwidth less than 2 nm in the far ultraviolet region (210–260 nm). The characteristic absorption peaks appear near 213 nm and 261 nm. Linearity assessment is based on the proportionality of measured absorbance to concentration at these peaks within the specified range.

Features and Purposes
  • Concentration range: 6 – 24 mg/L in 0.1 M HCl
  • Certifies absorbance linearity at 213 nm and 261 nm wavelengths
  • Suitable for spectrophotometers with bandwidth < 2 nm
  • Typical absorbance values up to approximately 1.15 A; higher concentrations available for absorbances up to 2.4 A (not recommended for linearity above 1.0 A)
  • Calibration certificates provided with bandwidth 1.0 nm measured values; values at other bandwidths available on request
  • Available as individual concentration references or as a set containing four concentrations and the blank cell
DOCUMENTS AND RESOURCES
Certified Reference Materials for Spectroscopy
Starna Cell Catalogue Micro Rectangular with Lid and Stopper
Nicotinic Acid UV Absorbance Reference Material for Spectrophotometer Calibration
PRODUCT SHEET

Nicotinic Acid (210 – 260 nm)

Nicotinic Acid Reference Material consists of solutions with concentrations ranging from 6 to 24 mg/L prepared in 0.1 M hydrochloric acid. These are contained in high quality far UV quartz cells and supplied alongside a 0.1 M hydrochloric acid blank cell.

This material is designed to qualify the accuracy and linearity of the absorbance scale of spectrophotometers with a bandwidth less than 2 nm in the far ultraviolet region (210–260 nm). The characteristic absorption peaks appear near 213 nm and 261 nm. Linearity assessment is based on the proportionality of measured absorbance to concentration at these peaks within the specified range.

Features and Purposes
  • Concentration range: 6 – 24 mg/L in 0.1 M HCl
  • Certifies absorbance linearity at 213 nm and 261 nm wavelengths
  • Suitable for spectrophotometers with bandwidth < 2 nm
  • Typical absorbance values up to approximately 1.15 A; higher concentrations available for absorbances up to 2.4 A (not recommended for linearity above 1.0 A)
  • Calibration certificates provided with bandwidth 1.0 nm measured values; values at other bandwidths available on request
  • Available as individual concentration references or as a set containing four concentrations and the blank cell
DOCUMENTS AND RESOURCES
Certified Reference Materials for Spectroscopy
Starna Cell Catalogue Micro Rectangular with Lid and Stopper
Nicotinic Acid UV Absorbance Reference Material for Spectrophotometer Calibration

Contact us to discover the offer dedicated to this product!