PRODUCT SHEET

Deep UV Reference (190 – 230 nm)

The Deep UV Reference Material is designed for qualification of wavelength and absorbance scales in spectrophotometers operating within the deep ultraviolet range of 190 nm to 230 nm. It addresses the challenges inherent to deep UV spectrophotometry, including the variability of transmission in UV grade quartz below 200 nm.

This Reference comprises a proprietary TS8 solution exhibiting distinct absorption and transmission peaks in the deep UV region, contained alongside a solvent blank in a matched pair of 10 mm far UV quartz cells. Both cells are permanently heat-fused sealed to assure stability and reproducibility.

Features and Purposes
  • Certified absorbance qualification points at approximately 191 nm (1.2 A), 209 nm (0.6 A), and 226 nm (1.0 A)
  • Supplied with solvent blank in identically matched 10 mm far UV quartz cuvettes
  • Certified for wavelength qualification with values at bandwidths of 1.0 nm and 5.0 nm
  • Proprietary TS8 matrix ensures spectral stability and reproducibility
  • Calibration Certificate provides precise wavelength and absorbance values to be used exclusively for instrument qualification
DOCUMENTS AND RESOURCES
Certified Reference Materials for Spectroscopy
Starna Cell Catalogue - Micro Rectangular Spectrophotometer Cells
Deep UV Reference Material for Spectrophotometer Calibration 190 to 230 nm
PRODUCT SHEET

Deep UV Reference (190 – 230 nm)

The Deep UV Reference Material is designed for qualification of wavelength and absorbance scales in spectrophotometers operating within the deep ultraviolet range of 190 nm to 230 nm. It addresses the challenges inherent to deep UV spectrophotometry, including the variability of transmission in UV grade quartz below 200 nm.

This Reference comprises a proprietary TS8 solution exhibiting distinct absorption and transmission peaks in the deep UV region, contained alongside a solvent blank in a matched pair of 10 mm far UV quartz cells. Both cells are permanently heat-fused sealed to assure stability and reproducibility.

Features and Purposes
  • Certified absorbance qualification points at approximately 191 nm (1.2 A), 209 nm (0.6 A), and 226 nm (1.0 A)
  • Supplied with solvent blank in identically matched 10 mm far UV quartz cuvettes
  • Certified for wavelength qualification with values at bandwidths of 1.0 nm and 5.0 nm
  • Proprietary TS8 matrix ensures spectral stability and reproducibility
  • Calibration Certificate provides precise wavelength and absorbance values to be used exclusively for instrument qualification
DOCUMENTS AND RESOURCES
Certified Reference Materials for Spectroscopy
Starna Cell Catalogue - Micro Rectangular Spectrophotometer Cells
Deep UV Reference Material for Spectrophotometer Calibration 190 to 230 nm

Contact us to discover the offer dedicated to this product!

Compila il form per richiedere un preventivo.