PRODUCT SHEET

Glass Filter – Visible Qualification Microplate

This reference device incorporates six Starna glass filter Certified Reference Materials (CRMs) housed within a black anodised aluminium microplate designed to meet the Society of Biomolecular Screening (SBS) dimensional standards for a 96-well plate.

The microplate is intended for the qualification of 96-well plate readers using Starna’s recognized UV and visible reference materials. Neutral Density Filters are utilized for absorbance scale validation while the Holmium oxide glass serves to verify wavelength accuracy across the relevant spectral range.

Features and Purposes
  • Positions C2 to H2: Air blank
  • Positions C4 to H4: Neutral Density Glass – 30% Transmittance (0.5 Absorbance)
  • Positions C6 to H6: Neutral Density Glass – 10% Transmittance (1.0 Absorbance)
  • Positions C8 to H8: Neutral Density Glass – 3% Transmittance (1.5 Absorbance)
  • Positions C10 to H10: Neutral Density Glass – 1% Transmittance (2.0 Absorbance)
  • Positions C12 to H12: Holmium Glass
  • Certified absorbance values for neutral density filters at 440, 465, 546.1, 590, and 635 nm
  • Holmium filter has 11 certified peak absorbance values between 240 nm and 640 nm
  • Compatible with all standard Starna solid filter CRMs in the Starna microplate format
DOCUMENTS AND RESOURCES
Certified Reference Materials for Spectroscopy
Starna Cell Catalogue Original Micro Rectangular Spectrophotometer Cells
UV and Visible Plate Reader Qualification Reference
PRODUCT SHEET

Glass Filter – Visible Qualification Microplate

This reference device incorporates six Starna glass filter Certified Reference Materials (CRMs) housed within a black anodised aluminium microplate designed to meet the Society of Biomolecular Screening (SBS) dimensional standards for a 96-well plate.

The microplate is intended for the qualification of 96-well plate readers using Starna’s recognized UV and visible reference materials. Neutral Density Filters are utilized for absorbance scale validation while the Holmium oxide glass serves to verify wavelength accuracy across the relevant spectral range.

Features and Purposes
  • Positions C2 to H2: Air blank
  • Positions C4 to H4: Neutral Density Glass – 30% Transmittance (0.5 Absorbance)
  • Positions C6 to H6: Neutral Density Glass – 10% Transmittance (1.0 Absorbance)
  • Positions C8 to H8: Neutral Density Glass – 3% Transmittance (1.5 Absorbance)
  • Positions C10 to H10: Neutral Density Glass – 1% Transmittance (2.0 Absorbance)
  • Positions C12 to H12: Holmium Glass
  • Certified absorbance values for neutral density filters at 440, 465, 546.1, 590, and 635 nm
  • Holmium filter has 11 certified peak absorbance values between 240 nm and 640 nm
  • Compatible with all standard Starna solid filter CRMs in the Starna microplate format
DOCUMENTS AND RESOURCES
Certified Reference Materials for Spectroscopy
Starna Cell Catalogue Original Micro Rectangular Spectrophotometer Cells
UV and Visible Plate Reader Qualification Reference

Contact us to discover the offer dedicated to this product!

Compila il form per richiedere un preventivo.

Compila il form per richiedere un preventivo.